EasyManua.ls Logo

Nord Drivesystems NORDAC LINK SK 155E-FDS - Configuration of Option Slots of the Control Level

Nord Drivesystems NORDAC LINK SK 155E-FDS
116 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Assembly and installation
BU 0155 en-3520 31
2.2.2.2 Configuration of option slots of the control level
The option slots M1 to M8 are designed for M12 plug connectors. The device-relevant assignment of
the connections or functions of the individual option slots is directly printed on the optional slot.
Option slot Option type Function Relevant
parameter
Comment
M1
a
No option
b
Initiator 1/2
BDI1
P420[-09]
BDI2
P420[-10]
M2
a
No option
b
Initiator 2
BDI2
P420[-10]
M3
a
No option
b
Actuator 1/2
DOUT1
P434[-01]
DOUT2
P434[-02]
M4
a
No option
b
Actuator 2
DOUT2
P434[-02]
M5
a
No option
b
Initiator 3/4
DIN1
P420[-01]
DIN2
P420[-02]
c
Initiator 4/5
DIN2
P420[-02]
DIN3
P420[-03]
d
PROFIBUS DP (input)
PBR
(Bus In)
only SK 1x5E-FDS-…PBR
M6
a
No option
b
Initiator 4
DIN2
P420[-02]
M7
a
No option
b
Initiator 3/4
DIN1
P420[-01]
DIN2
P420[-02]
c
PROFIBUS DP (output)
PBR
(Bus Out)
only SK 1x5E-FDS-…PBR
M8
a
No option
b
24 V DC supply
1)
24VI
c
AS-Interface (“AUX“)
AUX
only SK 1x5E-FDS-…Axx
d
AS-Interface (“AS-i”)
ASI
e
AS-Interface (“AXS“)
AXS
f
AS-Interface (“ASS“)
ASS
1)
The 24 V DC control voltage can also be supplied via M8 c (AUX), M8 e (AXS) or the option slots X1 or Z1Z4 of the
connection level.