5 Parameter
BU 0155 en-3520 89
5.2.7 Information
P700 Current operating status RD
Display range
0.0 … 25.4
Arrays
[-01] =
Current error
Current active error message (not acknowledged)
[-02] =
Current warning
Current existing warning
[-03] =
Reason for switch-on
block
Current existing reason for an active switch-on block
Description
Display of current messages about operating status
Display values
Section 6 "Operating status messages"
P707 Software version
Display range
0.0 … 9999.0
Arrays
[-01] =
Version
Version number (e.g.: V1.0)
[-02] =
Revision
Revision number (e.g.: R1)
[-03] =
Special version
Special version of hardware/software (e.g. 0.0). The value “0”
means “Standard version”.
Description
Display of software version (firmware version) of device
P708 Digital input status. RD
Display range
0000 0000 0000 … 0111 1111 1111
(bin)
0000 … 07FF
(hex)
Description
Display of switching status of the digital inputs
Display values
Value (Bit) Meaning
0
Digital input 1
Switching status of digital input 1
1
Digital input 2
Switching status of digital input 2
2 Digital input 3
Switching status of digital input 3
3 PTC input
PTC resistor input switching status
4
Bus In Bit 0
Signal status Bus In Bit 0
5
Bus In Bit 1
Signal status Bus In Bit 1
6 Bus In Bit 2
Signal status Bus In Bit 2
7 Bus In Bit 3
Signal status Bus In Bit 3
8
Digital input 1 BUS
Switching status of Bus digital input 1
9
Digital input 2 BUS
Switching status of Bus digital input 2
10 STO input
Signal status STO input
P709 Potentiometer status RD
Display range
0,0 … 100,0 %
Arrays
[-01] = DIP switch S1
Actual value in % of 3.6 A (SK 1xxE-FDS-151-…), or
Actual value in % of 7.5 A (SK 1xxE-FDS-301-…)
[-02] =
Potentiometer P1
Actual value in % of 25.6 s
[-03] =
Potentiometer P2
Current value in % of 100 % start voltage
[-04] =
Potentiometer P3
Current value in % of 25.6 s
Description
Display of the set values of DIP switch S1 or potentiometer P1P3,
relative to
the
particular end values of the scale (in %)

Table of Contents