EasyManua.ls Logo

Nord Drivesystems NORDAC LINK SK 155E-FDS - Page 88

Nord Drivesystems NORDAC LINK SK 155E-FDS
116 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NORDAC LINK (SK 155E-FDS / SK 175E-FDS)Users Manual for Motor Starters as Field Distributors
88 BU 0155 en-3520
P580 Error in the event of overtemp. RF
Setting range
0 … 1
Other applicable parameter(s): P108, P427
Factory setting
{ 1 }
Description
Fault shut-off due to overtemperatureselection of whether an over temperature error
(PTC) should lead to a warning or a fault shut-off.
Setting values
Value Meaning
0
Off
Warning (
C002
) due to overtemperature
1
On
Fault message (E002) and shut-off of device due to
overtemperature
P581 Phase sequence detection RF
Setting range
0 … 1
Other applicable parameter(s): P130, P428
Factory setting
{ 0 }
Description
Analysis of phase sequence of supply network by the device and automatic adaptation
of rotary field of motor to the required direction of rotation.
Note
As long as parameter P130=0 is set, phase sequence detection is determined via the
DIP switch S2-DIP2. In this case the parameter can only be read, but not changed. It
then corresponds to the setting that is determined by the DIP switch.
Setting values
Value Meaning
0 Off
The direction of rotation of the motor is determined by the direction
of rotation of the supply network.
1 On
The direction of rotation of the motor is determined by the enable
direction.
P582 Manual brake release RF
Setting range
0 … 1
Other applicable parameter(s): P420
Factory setting
{ 0 }
Description
Definition of conditions for releasing a connected electro-mechanical brake
Note
DANGER! With certain drive tasks (e.g. lifting gear) it can be dangerous to release of
the brake without the drive running (risk of raised load falling)!
Setting values
Value Meaning
0
Off
The brake is only released if the motor is enabled.
1
On
The brake is released even if the motor has not been enabled (e.g.
if a drive is to be moved for revision work).
Pay attention to note!