4 Commissioning
BU 0155 en-3520 53
4.2.2.1 Parameterisation
The use of a control and parametrisation unit (SK CSX-3H/ SK PAR-3H), NORDAC ACCESS BT with
the NORDCON APP or the NORDCON software is required to adjust the parameters. The following
displays the most important parameters, depending on the setting of parameter P130:
Parameter group Parameter numbers Functions Remarks
Basic parameter
P102 … P103
Acceleration and expiration
time
Factory setting:
Potentiometer value P3
P108
Disconnection mode
Factory setting:
DIP switch value S2-DIP3/4
P130
Parameter source
P130=0 Pot/Switch
P130=1 Flash memory
P130=0 (factory setting):
Potentiometer (P1-P3) and
DIP switch (S1, S2) effective
P130=1:
Parameter settings effective
Motor data
P203
Motor current rating
Factory setting:
S1-DIP1...4 value
P210
Initial voltage
Factory setting:
Potentiometer value P2
Control terminals P420, P434 Digital inputs and outputs Factory setting:
See parameter descriptions
Additional
parameters
P570
Reverse lockout time
Factory setting:
Potentiometer value
P1
Table 5: Parameters and functions depending on P130