5 Parameter
BU 0155 en-3520 93
P749 Status of DIP switch RD
Display range
0000 00001111 1111
(bin)
00 … FF
(hex)
0 … 255
(dec)
Description
Display of switch status of DIP switch
(S1, S2)
.
Display values
Value (Bit) Meaning
0
DIP switch 1
Switching status of DIP switch element 1
1
DIP switch 2
Switching status of DIP switch element 2
2 DIP switch 3
Switching status of DIP switch element 3
3 DIP switch 4
Switching status of DIP switch element 4
P752 Changeover relay error RD
Display range
0 … 10
Description
Display of the errors caused by a changeover relay (E18.3). The changeover relay
performs the change of direction of the motor in reversing mode.
Note
After the 10th error occurs the device is no longer operational and must be sent for
repair.
This parameter is only available for devices with reversing function (SK 175E-FDS).
P753 Bypass relay error RD
Display range
0 … 10
Description
Display of the errors caused by a bypass relay (E18.4).
The bypass relay bypasses the thyristor module after completion of the acceleration
phase.
Note
After the 10th error occurs the device is no longer operational and must be sent for
repair.
The parameter is only available for devices with soft start function (SK 155E-FDS,
SK 175E-FDS).
P762 Phase U voltage RD
Display range
0 … 500 V
Description
Display of current voltage of phase U
Note
The value of P722 can differ because of the measuring procedure, in spite of having
symmetrical output voltages.
P763 Phase V voltage RD
Display range
0 … 500 V
Description
Display of current voltage of phase V
Note
The value of P722 can differ because of the measuring procedure, in spite of having
symmetrical output voltages.
P764 Phase W voltage RD
Display range
0 … 500 V
Description
Display of current voltage of phase W
Note
Because of the measuring procedure, the value of P72 can deviate in spite of
symmetrical output voltages.
P780 Device ID
Display range
0 … 9 and A … Z
(char)
Arrays
[-01] =
… [-14]
Description
Display of the serial number (14-digit) of the device.
Note
Display via NORDCON: as a contiguous serial number of the device
Display via bus: ASCII code (decimal). Each array must be read out separately.