Defining Electronic Pressure Settings and Monitoring
Alert Settings
Use Electronic Pressure Adjust to remotely change and monitor system
melter pressure. You can optionally decide if you want to receive pressure
alerts when the system pressure, hydraulic or pneumatic exceeds the
defined thresholds.
NOTES:
S The melter will go into an Alert condition only if the pressure meets or
exceeds the high/low thresholds for more than 10 seconds.
S You can change the pressure scaling from the System Settings |
Preferences menu. The default is Pneumatic
S Press on the OLED panel to clear and reset any Alert, Fault, or
Stop condition.
Electronic Pressure Alert and Monitoring
You will receive an alert alarm, if pressure is out of tolerance for more than 10
seconds.
NOTES:
S A “+” symbol appears next to the High Pressure Alert threshold setting
indicating the offset or delta from the Maximum Pressure Set Point Range
setting.
S A “-” symbol appears next to the Low Pressure Alert threshold setting
indicating the offset or delta from the Minimum Pressure Set Point Range
setting.
1. Select Pressure Setting Range Alert and press the on the
Navigation pad to toggle Pressure Alert to Enabled or Disabled. The
default is Enabled.
2. Select Low Pressure Alert Threshold, press >, then enter the amount
of pressure offset below the set point before the melter enters into an
Alert condition. When done, press the
on the Navigation pad.
Pressure Default Minimum Maximum
PSI (-)10 from
set point
(-)5 from
set point
(-)70 from
set point
BAR
(-)0.69 from
set point
(-)0.34 from
set point
(-)4.83 from
set point
kPa (-)69 from
set point
(-)34 from
set point
(-) 483 from
set point