System Settings
System I/O
Output
OLED User Interface
78
Part 1128351_02
E 2020 Nordson Corporation
Assigning Outputs
1. Select Output and press >.
* If you have the optional Legacy I/O board installed, then select from
either Standard Legacy to assign outputs.
The default Standard Output #1 is Disabled.
2. Decide if you want to Invert (reverse the polarity) of the Output. Select
Invert and press
to change the polarity. The default, is not inverted
(active high).
3. Use the Up key on the Navigation pad to select Assign, then press > to
view the output menu list selection. Use the Up/Down keys on the
Navigation pad to scroll through the list. Press to assign the output
selection you want. When done, press < to return to the Input/Output
menu.
4. Decide if you want to test the current output assignment. Select Test,
then press
to toggle Start/Stop the test.
5. Press
to return to the Home screen.
NOTES:
S You can assign the same output selection to multiple outputs.
S You can assign light tower outputs using standard outputs.
S The default output selections for the with the Legacy I/O expansion kit are
as follows:
‐ Output #1: Temperature Ready
‐ Output #2: System Fault
‐ Output #3: Tank Low