Managing Heated Zones
There are two types of heated zones:
S Internal Zones: Tank and the manifold
S External Zones: Connected hoses and applicators
Enabling/Disabling and Changing Zone Set Point
Temperatures
1. Navigate and select the zone you want to enable/disable or change its
set point temperature and press > on the Navigation pad.
2. Do the following to continue:
S To Enable/Disable an external zone - Press the on the Navigation pad
to toggle the zone to Enable or Disable. When done, press the < on the
Navigation pad to return to the previous screen.
S To change the set point temperature, press the Up/Down keys on the
Navigation pad to select the zone you want to change its set point
temperature, then press > and enter the set point temperature you want.
When done, press the
.
Zone Default Minimum Maximum
Internal Zones 177_ C
(351
_ F)
40_ C
(100_ F)
204_ C
(400_ F)
External Zones
177_ C
(351_ F)
40_ C
(100_ F)
232_ C
(450_ F)
NOTES:
S By default, internal zones are enabled, and all external zones are
disabled.
S Select Global Set Point to make all zones (enabled or disabled) the
same set point temperature.
S Internal zones (tank and manifold) cannot be disabled. You can only
change their set point temperatures.
S Although there are two internal zones (tank and manifold), changing one
internal zone automatically changes the other. You cannot have two
different internal zone set point temperatures.