System Settings
Manual Setback
Auto Exit Time
Temperature Settings
Setback Settings
OLED User Interface
52
Part 1128351_02
E 2020 Nordson Corporation
Defining Manual Setback - Auto Exit Time
Use Manual Setback - Auto Exit time to define the amount of time to
elapse before the melter exists Setback mode after you manually place it into
Setback.
Typically, you use this option when you want the melter to enter Setback for
shift changes and breaks, thereby preventing the adhesive from charring or
degrading.
1. Press the
on the Navigation pad to toggle Manual Setback - Auto Exit
Time to Enabled or Disabled. The default is Disabled.
2. Select Auto Exit Time Delay, press >, and enter the amount of time you
want the melter to exit Setback. The default is 45 minutes, the minimum
is 1 minute, and the maximum is 180 minutes. When done, press
.
3. Press < to return to the Setback Settings menu or
to return to the
Home screen.
NOTES:
S Press the Master control button to toggle Off (exit) Automatic
Setback.
S While in Setback, the System Status indicator is Blue.
S Press on the OLED panel to clear and reset any Alert, Fault, or
Stop condition.