OLED User Interface
35
Part 1128351_02
E 2020 Nordson Corporation
3. Select High Pressure Alert Threshold, press >, then enter the amount
of pressure offset above the set point before the melter enters into an
Alert condition. When done, press the
on the Navigation pad.
Pressure Default Minimum Maximum
PSI (+)10 from
set point
(+)5 from
set point
(+)70 from
set point
BAR
(+)0.69
from set
point
(+)0.34
from set
point
(+)4.83
from set
point
kPa (+)69 from
set point
(+)34 from
set point
(+)483 from
set point
4. When done, press < to return to the Pressure Control Settings menu or
to return to the Home screen.
Electronic Pressure Control Settings
1. Select Minimum Pressure Set Point Range, press >, then enter the
minimum pressure you want to use while in production. When done,
press the
on the Navigation pad.
Pressure Default Minimum Maximum
PSI 10 10 100
BAR 0.69 0.69 6.90
kPa 69 69 690
2. Select Maximum Pressure Set Point Range, press >, then enter the
maximum pressure you want to use while in production When done,
press the
on the Navigation pad
Pressure Default Minimum Maximum
PSI 70 20 100
BAR 4.83 1.38 6.90
kPa 483 138 690
3. Go to the next page to optionally define pressure alerts. Otherwise,
press < to return to the Pressure Control Settings menu or
to return
to the Home screen.