Connect Power
NOTES:
Use only the supplied power cord.
Ensure that the power source is located near the equipment
and is easily accessible.
Use only on a circuit with a fuse or circuit breaker that is
20A or less.
1. Connect the power cord to the back of each controller
and to your local power source.
2. Connect a 16 AWG (1.3 mm) wire to the chassis
grounding screw on the rear of the chassis using a
toothed grounding lug. The wire must have green
insulation with a yellow stripe or must be noninsulated
(bare).
3. Attach the opposite end of the wire to a permanent earth
ground using toothed washers or a toothed lug.
Connect the Pump Motor Cables
Connect the 797PCP-2K pump motor cables to the MOTOR1
and MOTOR2 ports on the controller.