ValveMate 7197PCP-2K Controller
18 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Purge the Pumps
Before creating any programs or placing the system into operation for the first time, each pump must first be purged
through the manifold (without a mixer installed), and then both pumps must be purged at the same time through an
installed mixer.
Risk of equipment damage. Do not operate a 797PCP-2K without material. Excessive friction of dry components
can damage the pump.
CAUTION
1. Ensure that each pump has been calibrated. Initial purging will work only after a calibration has been performed.
2. Refer to the pump purging procedure in the installation section of the pump manual to purge each
797PCP-2K pump through the manifold. Return here to continue.
3. Before installing the mixer, determine and enter the correct settings for your Part A (Pump 1) and
PartB (Pump 2) components. Nordson EFD recommends using the Volume program for this part of the
installation process. Refer to “Appendix B, Example Volume Program” on page51 to complete the
installation process.
The system is now ready for routine operation. Continue to “Programming” on page20 to create dispense
programs for pump operation.
Installation (continued)