Calibration
Calibration allows the controller to determine a baseline for the resistance between the rotor and the stator. Perform
a calibration as follows:
• Before the initial purge of a pump during installation
• After replacing a cable
NOTE: Calibration allows the use of cable lengths up to 50 m (164 ft) without the loss of accuracy and
repeatability.
• After every rotor or stator replacement
1. Ensure that there is material in the pump.
2. On the Main screen, select CALIBRATE.
3. Select the Calibrate radio button.
4. Select SUBMIT. The system runs until calibration is complete.
5. Select BACK to return to the Main screen.
NOTE: When you select a program, the Calibrate radio button automatically deselects.