ValveMate 7197PCP-2K Controller
30 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Variable Range Description
Info n/a Select to view information about the current screen, including the range
limits for settings.
RPM 10–150 (RPM) Sets the motor speed in RPM; for guidance on setting the RPM, refer to
“Maximum Motor Speed Based on Viscosity” on page47.
Reverse % 0–200 (%)
(adjustable in
increments of 1%)
Based on the percentage of rotation, sets the suck-back to reverse the
motor at the end of a dispense cycle to prevent drooling.
Dispense
Volume (mL)
0.001–15000.00 (mL)
(adjustable in
increments of 0.001)
Sets the amount of material (in mL) that will be dispensed for each cycle
of the pump.
Pump Size 0.01 mL, 0.05 mL, or
0.15 mL
Select the size of the pump for which you are creating the program.
Correction
Factor
0.1–2.00
(adjustable in
increments of 0.01)
Because rotors and stators may not be perfectly matched, the Correction
Factor linearly scales the output to ensure that the expected amount is
deposited every time.
Programming (continued)
Volume Programs
Use a Volume program to dispense primarily based on volume. When a Volume program is used, the pump
dispenses until the specified amount (in milliliters) has been deposited.
NOTE: For an example of how to create a Volume program, including how to use Correction Factor and Reverse %,
refer to “Appendix B, Example Volume Program” on page51.
1. Navigate to the Volume program screen.
2. (Touchscreen interface only) Select the pump button to toggle between the Pump 1 and Pump 2 screens.
3. Select the ENABLE VOLUME PROGRAM radio button.
NOTE: If you don’t enable the program, the system will not save any entered settings.
4. Enter the desired settings, referring to the table below for detailed information on each variable.
5. Select SUBMIT to save the settings. The variable table shows the saved settings.
6. To save the values you entered as a program in the Program Library, refer to “Saving a Program to the Program
Library (Save Screen)” on page34.
Volume program screen, touchscreen interface
Volume program screen, web interface
4
2
3
ValveMate 7197PCP-2K Touchscreen 7197PCP-2K Web
5
4
3
5