ValveMate 7197PCP-2K Controller
General Troubleshooting
Problem Possible Cause Corrective Action
Controller not powering
on
Power supply not connected Ensure that the power cord is properly connected.
Pump not dispensing Foot pedal not connected or
loose
Ensure that the foot pedal is properly connected.
Pump motor cable not
connected, loose, or damaged
Disconnect and lock out power to the controller
Ensure that the pump motor cable is properly
connected. Replace the cable if it is damaged.
ESTOP signal not connected Ensure that the ESTOP jumper is properly installed in
the I/O port on the back of the controller.
The pump will dispense only if pins 1 and 2 (Estop_H
and Estop_L) and connected.
Entered value will not
save
Value not within range limits The values entered for program variables must
be within the specified range limits. Refer to the
information table for each program type for range
limits.
Program not enabled Ensure that the program is enabled by selected the
enable / disable radio button; program variables can
be changed only after a program is enabled.