430 Chapter 39 Hardware procedures
NN10600-175 6.1S2
Removing a Multiservice Switch 7480
Remove a Nortel Networks Multiservice Switch 7480 after you have removed
the power supplies, processor cards and cooling unit drawer.
Prerequisites
Procedure steps
1 If the shelf used an external alarm, disconnect the external alarm cable
from the rear of the device.
2 Use a 1/8-in. screwdriver to disconnect the cooling unit power cord from
the “C.U. Power” connector on the back of the shelf assembly. See the
figure
“Cooling unit power cord” (page 501).
3 Use a 3/8-in. socket wrench to disconnect the shelf grounding cable from
the cabinet or frame and tape the cable to the rear of the shelf next to the
shelf assembly grounding stud. See the figure
“Shelf assembly grounding
stud” (page 232).
4 Remove the air filter assembly. If the air filter assembly is spring-loaded,
carefully press and release the center of the air filter cartridge to
WARNING
Risk of injury
The shelf assembly weighs 20.9 kg (46 lb). You need two
people to perform this procedure.
WARNUNG
Verletzungsgefahr
Die Regalkomponente wiegt 20,9 kg. Zur Montage sind
zwei Personen erforderlich.
CAUTION
Risk of damage to equipment by moving
When moving an uncrated cabinet or shelf assembly,
protect it from strain, shock, impact, and vibration. Lack
of protection can damage or warp the equipment.