Basic Components Product Description
XPIQ PN 51013:C 7/01/03 15
XPIQ-MB Features
Four Class B speaker circuits which are continuously supervised in On and Off state
XPIQ-CA Class A option board for conversion of four Class B speaker circuits to four Class
A speaker circuits
Accepts four audio riser channels from XPIQ-AIB4 option board
Four amplifier slots
Continuously supervised amplifiers
All-call local page capability with optional RM-1(SA) remote microphone and XPIQ-RMI
Two independent user configurable tone generators either for riser backup or as a main tone source
Supports routing of all-call page from single remote microphone to other XPIQ-MBs in the
same cabinet
Supports a variety of backup configurations
1 to 1 backup
2 to 1 backup
3 to 1 backup
2 to 2 backup
1 to 1 external backup (backup amplifier in another XPIQ)
2 to 1 external backup (backup amplifier in another XPIQ)
3 to 1 external backup (backup amplifier in another XPIQ)
4 to 1 external backup (backup amplifier in another XPIQ)
Note: Refer to "XPIQ Audio Amplifier Installation" on page 38 for rules that apply when using more
than one type of audio amplifier.
Supports backup amplifier sharing between two or more XPIQs within the same cabinet
Four Class B or two Class A firefighter telephone zones capable of distinguishing open, short
and off-hook states
Busy tone on firefighter telephone circuits
Supervised firefighter telephone riser input with in and out terminals
Alternate use of firefighter telephone circuits as four Class B or two Class A NACs, each
rated at 2A, 24 VDC
XPIQ-PS(E) power supply control/supervision that includes AC, battery and charger
monitoring
AC trouble delay option (none, 8 or 16 hour delay)
Ground fault detection
Serial port for configuration download from PC
Easy software upgrading accomplished by downloading from PC via serial port
Nonvolatile memory for storing configuration data
Pluggable terminal blocks for field wiring
Background music input terminal block
Ten position background music volume control switch
Accessory trouble input