5.4.3 Execution on the Machine
5.4.3.1 Optional Stop and Block Skip Enable
A part programme may contain functions which, when enabled, modify its execution (functions for debugging for
example). These include:
- optional stops (M01),
- block skips (/ at start of block).
When optional stops are enabled by the operator, all "M01" functions encountered in the programme are treated as
"M00" functions (See Programming manual). Otherwise, the "M01" functions are ignored.
When block skips are enabled by the operator, all blocks preceded by "/" are ignored. Otherwise, the blocks are
executed normally.
Optional stop enable
The optional stop indicator (M01) in the status window (See 3.1.3) indicates that the optional stop function is enabled.
Actions
Enable or disable the optional stop function.
M01
The optional stop indicator disappears or is displayed accordingly.
REMARK The
M01
key does not exist on the 9" and 10" operator panels. Optional stops are
enabled on the machine panel.
Block skip enable
The block skip indicator (/) in the status window (See 3.1.3) indicates that the block skip function is enabled.
Requirements
No mode being executed.
Actions
Enable or disable the block skip function.
The block skip indicator disappears or is displayed accordingly.
REMARK The key does not exist on the 9" and 10" operator panels. Block skips are
enabled on the machine panel.