5 - 92 en-938821/2
5.9.6 Loading from the NUM Diskette Drive
The commands described below are used for dialogue with the drive.
Requirements
Link established with the diskette drive and presence of a serial line configured for the Kermit protocol (see C.2.3).
Drive on.
"Kermit" serial line selected.
The reduced "FILE LOADING" menu (See 5.9.2) is displayed.
General Remarks
Data format
The data (part programmes and tool offsets) backed up on the NUM diskette drive have a special format which differs
from that of the other backup modes (load/unload modes, APA10, etc.). This means that the data backed up in the
other modes cannot be loaded from the NUM diskette drive.
The part programmes loaded must begin with the character “%” and end with ASCII code “10” (“0A” hexadecimal).
Interrupted transmission
!
CAUTION
If transmission is accidentally interrupted, not all the data are loaded. Check that transmis-
sion was completed normally (no error message displayed and red LED on drive not lit) to be
sure the programmes saved will run correctly on the machine.
5.9.6.1 Loading Part Programmes from the Num Diskette Drive
Actions
Select "PROGRAMMES".
)
0
The "SERVICE DISKETTE: LOAD PROGRAMME" page is displayed with the softkeys:
CD
DIR CD..
HELP
OUT
TRANSF.
CD \
ABORT
The following dialogue line is displayed:
Transfer>