8 - 44 en-938821/2
Incidents
Error in password
Display of the message:
INCORRECT PASSWORD
The "RESIDENT MACROS" menu displayed after a few seconds.
The programme specified does not exist in the protected area
Display of the message:
PROGRAMME DOES NOT EXIST
If required continue the operations with other programmes.
Verifying a programme without unloading it
The programme to be verified must already be present on the storage medium.
In answer to the question:
UNLOAD
? (Y,N)
Select not to unload the programme.
N
Display of the "VERIFY PROTECTED ZONE" page and the message:
VERIFY
and the dialogue line
? (Y,N)
Verify the programme (See 8.8.7.3).
8.8.7.2 Global Unloading of Protected Programmes (Backup Copy)
Requirements
CNC connected to the peripheral (See C.2).
Peripheral ready to receive binary data (See peripheral manual).
CNC transmission baud rate (See 8.3) conforming to the peripheral reception baud rate.
Unloading dialogue line displayed (See 8.7.7).
Programmes present in the protected area.
Actions
Enter "%".
Display of the message:
UNLOAD