Index
(hex)
Sub-
index
(hex)
Pa-
rame-
ter No.
Function name Monitor or data range
Default
data
Set-
ting
dur-
ing
RUN
Unit
PDO
map
60 H195 DC Injection
Braking Startup
Time
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.00: Disable
0.01 to 30.00
0
s Possible
61 H196 Reserved Do not use. --- --- --- ---
62 H197 User password 1
Mode selection
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0: All parameters cannot be changed
1: Those other than favorite parame-
ters cannot be displayed or changed
Select protection mode for user
password 1.
0
--- Possible
63 H198 User Password 1
Setting/Verifica-
tion
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0000 to FFFF hex
0
--- Possible
64 H199 User Password 1
Setting
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0: Disable
1: Enable
0
--- Possible
3051 0A H309 Output Terminal
[DO1] ON Delay
T
ime
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.0 to 100.0
0.00 --- s Possible
0B H310 Output Termi-
nal[DO1] OFF
Delay T
ime
0E
H313 Output Terminal
[ROA, ROB] ON
Delay Time
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.0 to 100.0
0.00 --- s Possible
0F H314 Output Terminal
[ROA, ROB] OFF
Delay Time
10
H315 Logical Expres-
sion 1 Operation
Target 1
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0 to 241 (normally-open output)
1,000 to 1,241 (normally-close out-
put)
Refer to 8-2-2 Multifunction Output
Selection on page 8-28.
27, 100, 206, 207, and 208 cannot
be selected.
0
--- --- Possible
11 H316 Logical Expres-
sion 1 Operation
T
arget 2
Appendices
A-142
M1 Series EtherCAT Type User’s Manual (I670)