Appendix
A-12
Appendix
CompoWay/F
Setting data
Attributes
Variable type
Address Address
Modbus
Character Setting (monitor) value Character
Default
value
Decimal point
position
Units
Set value
C7
−
−
−
−
0000
0004
0005
0006
0007
0008
0009
000A
000B
000C
000D
000E
000F
0010
0011
0012
0013
0014
−
−
−
−
0700
0708
070A
070C
070E
0710
0712
0714
0716
0718
071A
071C
071E
0720
0722
0724
0726
0728
bank
at
cmwt
spmd
c-sc
c-db
of-r
hys
chys
cp
c-cp
db
oc-h
spru
sprh
sprl
m -s
m -s
m -e
m -e
orl
corl
(0 to 7)
OFF (-1)
(0 to 8)
OFF (0)
ON (0)
Local SP (LSP)(0)
RSP (1)
H'00000001 to H'0000270F (0.01 to 99.99)
H'FFFFF831 to H'0000270F (-19.99 to 99.99)
H'00000000 to H'000003E8 (0.0 to 100.0)
H'00000001 to H'0000270F (0.01 to 99.99)
H'00000001 to H'0000270F (0.01 to 99.99)
H'00000002 to H'000003DE (0.2 to 99.0)
H'00000002 to H'000003DE (0.2 to 99.0)
H'00000001 to H'00000064 (0.1 to 10.0)
H'00000001 to H'000000C8 (0.1 to 20.0)
H'00000000: EU/sec: S (0)
H'00000001: EU/min: M (1)
H'00000002:EU/hour: H (2)
H'00000000 to H'0001869F
(0 to 99999 (0: Disabled SP ramp function) )
H'00000000 to H'0001869F
(0 to 99999 (0: Disabled SP ramp function) )
Standard: H'FFFFFFCE to H'0000041A (-5.0 to 105.0)
Heat / cool: H'FFFFFBE6 to H'0000041A
(-105.0 to 105.0)
H'FFFFFFFF:-1 (completely open)
H'00000000: 0 (hold)
H'00000001:1(completely open)
Standard: H'FFFFFFCE to H'0000041A (-5.0 to 105.0)
Heat / cool: H'FFFFFBE6 to H'0000041A
(-105.0 to 105.0)
H'FFFFFFFF:-1 (completely open)
H'00000000: 0 (hold)
H'00000001:1(completely open)
H'00000000 to H'000003E8
(0.0 to 100.0 (0.0: Limiter disabled) )
H'00000000 to H'000003E8
(0.0 to 100.0 (0.0: Limiter disabled) )
0 to 7
off, 0 to 8
off, on
lsp, rsp
0.01 to 99.99
-19.99
to
99.99
0.0 to 100.0
0.01 to 99.99
0.01 to 99.99
0.2 to 99.0
0.2 to 99.0
0.1 to 10.0
0.1 to 20.0
s, m, h
0 to 99999
0 to 99999
-5.0 to
105.0
-105.0
to
105.0
-1, 0, 1
-5.0 to 105.0
-105.0
to
105.0
-1, 0, 1
0.0 to
100.0
0.0 to
100.0
0
OFF
OFF
Local SP
(LSP)
1.00
0.00
50.0
0.10
0.10
20.0
20.0
2.0
0.8
M
0
0
0.0
0
0.0
0
0.0
0.0
−
−
−
−
−
%FS
%
%FS
%FS
Seconds
Seconds
%
%
−
EU
EU
%
−
%
−
%/S
%/S
−
−
−
−
2
2
1
2
2
1
1
1
1
−
According to
input type
According to
input type
1
−
1
−
1
1
CH
CH
Common
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
Bank No.
AT Execute/Cancel
Write via communication
SP mode (Remote/Local)*1
Cooling coefficient
Dead band
Manual reset value
Hysteresis (heat)
Hysteresis (cool)
Control period (heat)
Control period (cool)
Position proportional dead band
Open/Close hysteresis
SP ramp time unit
SP ramp rise value
SP ramp fall value
MV at stop
(standard / heat / cool)
MV at stop
(position proportional)
MV at PV error
(standard / heat / cool)
MV at PV error
(position proportional)
MV change rate limit (heat)
MV change rate limit (cool)
Adjustment level
"H' -" indicated in set values (monitor values) are values set by communication (monitor).