Setting list
A-17
Appendix
CompoWay/F
Setting data
Attributes
Variable type
Address Address
Modbus
Character Setting (monitor) value Character
Default
value
Decimal point
position
Units
Set value
CC 0000
0001
0002
0003
0004
0005
0006
0007
0008
0009
000A
000B
000C
000D
000E
000F
0010
−
0C00
0C02
0C04
0C06
0C08
0C0A
0C0C
0C0E
0C10
0C12
0C14
0C16
0C18
0C1A
0C1C
0C1E
0C20
−
i1-t
i1du
i2-t
i2du
i3-t
i3du
i4-t
i4du
inp.1
dsp.1
inp.2
dsp.2
dp
rsph
rspl
p dp
snc
amo
H'00000000:Pt100 (0)
H'00000001:Pt100 (1)
H'00000002:K (2)
H'00000003:K (3)
H'00000004:J (4)
H'00000005:J (5)
H'00000006:T (6)
H'00000007:E (7)
H'00000008:L (8)
H'00000009:U (9)
H'0000000A:N (10)
H'0000000B:R (11)
H'0000000C:S (12)
H'0000000D:B (13)
H'0000000E:W (14)
H'0000000F:4 to 20 mA (15)
H'00000010:0 to 20 mA (16)
H'00000011:1 to 5 V (17)
H'00000012:0 to 5 V (18)
H'00000013:0 to 10 V (19)
H'00000000: °C (0)
H'00000001: F (1)
Input 1: Same as input type
H'00000000:°C (0)
H'00000001: F (1)
Input 1: Same as input type
H'00000000: °C (0)
H'00000001: F (1)
Input 1: Same as input type
H'00000000: °C (0)
H'00000001: F (1)
Input lower-limit to input upper-limit
H'FFFFB1E1 (-19999) to scalling display value 2-1
Input lower-limit to input upper-limit
Scaling display value 1+1 to H'0000270F (99999)
H'00000000 to H'00000004 (0 to 4)
Temperature:
Lower limit of sensor setting range to upper limit of sensor setting range
Analog:
Larger of -19999 and "display value equivalent to input lower limit" to
smaller of 99999 and "display value equivalent to upper input limit"
Temperature:
Sensor setting range to upper limit of sensor setting range
Analog:
Larger of -19999 and "display value equivalent to input lower limit" to
smaller of 99999 and "display value equivalent to input upper limit"
H'00000000: OFF (0)
H'00000001: ON (1)
H'00000000:50 Hz (0)
H'00000001:60 Hz (1)
H'FFFFF831 to H'0000270F (-1999 to 9999)
0 to
19
c, f
0 to
19
c, f
0 to
19
c, f
0 to
19
c, f
Same as at left
Same as at left
Same as at left
Same as at left
0 to 4
Same as at left
Same as at left
off, on
50hz, 60hz
-1999
to
9999
2 *4
°C
2 *4
°C
2 *4
°C
2 *4
°C
4 *3
0
20 *3
100
0
1300
-200
ON
50 Hz
0
−
−
−
−
−
−
−
−
*2
EU
*2
EU
−
EU
EU
−
−
−
−
−
−
−
−
−
−
−
0
−
0
−
−
According to input type
According to input type
−
−
−
Common
Common
Common
Common
Common
Common
Common
Common
CH
CH
CH
CH
CH
CH
CH
CH
Common
Common
Input 1 type
Input 1 temperature units
Input 2 type
Input 2 temperature units
Input 3 type
Input 3 temperature units
Input 4 type
Input 4 temperature units
Scaling input value 1
Scaling display value 1
Scaling input value 2
Scaling display value 2
Decimal point position
Remote SP upper limit
Remote SP lower limit
PV decimal point display
Sensor induction noise reduction
Move to advanced function setting
level
Input initial setting level
"H' -" indicated in set values (monitor values) are values set by communication (monitor).
*1 .... Input type settings are 0 to 14 for temperature input and 15 to 19 for analog input as determined by the input type switch (under the unit).
*2 .... Determined by input type setting.
*3 .... Initializes to upper-and lower-limits of input when the input type is changed.
*4 .... The default value for the input type is "2" regardless of the setting of the input type switch.