4-25
CHAPTER 4 Adjustment
12) Perform the absolute reset from outside the safeguard enclosure.
13) After the absolute reset is completed, read the machine reference value dis-
played on the PB.
14) If the machine reference value is in the range between 40 and 60 (recom-
mended range), then the machine reference has been completely adjusted.
If it is outside the recommended range, then repeat the procedure that starts
in 5) to readjust it.