3.
In order to check the behavior of the Servomotor, right-click Data Trace Settings
and select Add - Data Trace from the menu to add a new data trace.
4.
Select Cyclic for the trace type.
5.
Adjust the sampling interval.
6.
Adjust the enable trigger condition.
7.
Click the Transfer Parameters from Drive after Trace Button to disable uploading
parameters.
Click the Execute Button.
Sysmac Studio is now waiting for the trigger.
8.
Align the Test Run Window and the Data Trace Window horizontally by docking
them.