9-21
9 Details on Servo Parameter Objects
G5-series AC Servomotors and Servo Drives User’s Manual (with Built-in EtherCAT Communications)
9-3 Vibration Suppression Settings
9
Set the notch frequency of resonance suppression notch filter 2.
The notch filter function is disabled if this object is set to 5000.
Refer to 11-7 Notch Filters on page 11-23.
Select the notch width of resonance suppression notch filter 2.
Increasing the setting value widens the notch width. Normally, use the default set value.
Refer to 11-7 Notch Filters on page 11-23.
Set the notch depth of resonance suppression notch filter 2.
Increasing the setting value shortens the notch depth and the phase lag.
Refer to 11-7 Notch Filters on page 11-23.
Set the notch frequency of resonance suppression notch filter 3.
The notch filter function is disabled if this object is set to 5000.
While the adaptive filter is enabled, the resonance frequency 1 that is assumed by the adaptive filter
is automatically set. If no resonance point is found, the value 5000 is set.
Refer to 11-6 Adaptive Filter on page 11-20 and 11-7 Notch Filters on page 11-23.
Select the notch width of resonance suppression notch filter 3.
Increasing the setting value widens the notch width. Normally, use the default set value.
While the adaptive filter is enabled, this object is set automatically.
Refer to 11-6 Adaptive Filter on page 11-20 and 11-7 Notch Filters on page 11-23.
3204 hex
Notch 2 Frequency Setting
Setting range 50 to 5000 Unit Hz
Default setting
5000 Data attribute B
Size 2 bytes (INT16) Access RW PDO map Not possible.
3205 hex
Notch 2 Width Setting
Setting range 0 to 20 Unit
Default setting
2 Data attribute B
Size 2 bytes (INT16) Access RW PDO map Not possible.
3206 hex
Notch 2 Depth Setting
Setting range 0 to 99 Unit
Default setting
0 Data attribute B
Size 2 bytes (INT16) Access RW PDO map Not possible.
3207 hex
Notch 3 Frequency Setting
Setting range 50 to 5000 Unit Hz
Default setting
5000 Data attribute B
Size 2 bytes (INT16) Access RW PDO map Not possible.
3208 hex
Notch 3 Width Setting
Setting range 0 to 20 Unit
Default setting
2 Data attribute B
Size 2 bytes (INT16) Access RW PDO map Not possible.