EasyManua.ls Logo

Omron R88M-K - Page 426

Omron R88M-K
730 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9 Details on Servo Parameter Objects
9-22
G5-series AC Servomotors and Servo Drives User’s Manual (with Built-in EtherCAT Communications)
Set the notch depth of resonance suppression notch filter 3.
Increasing the setting value shortens the notch depth and the phase lag.
While the adaptive filter is enabled, this object is set automatically.
Refer to 11-6 Adaptive Filter on page 11-20 and 11-7 Notch Filters on page 11-23.
Set the notch frequency of resonance suppression notch filter 4.
The notch filter function is disabled if this object is set to 5000.
While two adaptive filters are enabled, the resonance frequency 2 that is assumed by the adaptive
filter is automatically set. If no resonance point is found, the value 5000 is set.
Refer to 11-6 Adaptive Filter on page 11-20 and 11-7 Notch Filters on page 11-23.
Select the notch width of resonance suppression notch filter 4.
Increasing the setting value widens the notch width. Normally, use the default set value.
This object is automatically set when two adaptive filters are enabled.
Refer to 11-6 Adaptive Filter on page 11-20 and 11-7 Notch Filters on page 11-23.
Set the notch depth of resonance suppression notch filter 4.
Increasing the setting value shortens the notch depth and the phase lag.
When two adaptive filters are enabled, this object is set automatically.
Refer to 11-6 Adaptive Filter on page 11-20 and 11-7 Notch Filters on page 11-23.
3209 hex
Notch 3 Depth Setting
Setting range 0 to 99 Unit
Default setting
0 Data attribute B
Size 2 bytes (INT16) Access RW PDO map Not possible.
3210 hex
Notch 4 Frequency Setting
Setting range 50 to 5000 Unit Hz
Default setting
5000 Data attribute B
Size 2 bytes (INT16) Access RW PDO map Not possible.
3211 hex
Notch 4 Width Setting
Setting range 0 to 20 Unit
Default setting
2 Data attribute B
Size 2 bytes (INT16) Access RW PDO map Not possible.
3212 hex
Notch 4 Depth Setting
Setting range 0 to 99 Unit
Default setting
0 Data attribute B
Size 2 bytes (INT16) Access RW PDO map Not possible.