9 Details on Servo Parameter Objects
9-24
G5-series AC Servomotors and Servo Drives User’s Manual (with Built-in EtherCAT Communications)
First set Damping Frequency 2 (3216 hex). Then reduce the setting if torque saturation occurs or
increase the setting to increase operation speed. Normally, use a setting of 0.
The upper limit of the set value is restricted to the smaller value of the corresponding damping
frequency or (2000 damping frequency).
Refer to 11-5 Damping Control on page 11-17 for more information on settings.
Set
damping frequency 3 to suppress vibration at the end of the load in damping control.
Measure the frequency of vibration at the end of the load and make the setting in units of 0.1 Hz.
Setting frequency is 1.0 to 200.0 Hz. The function is disabled if the setting is 0 to 0.9 Hz.
Refer to 11-5 Damping Control on page 11-17 for more information on settings.
First set
Damping Frequency 3 (3218 hex). Then reduce the setting if torque saturation occurs or
increase the setting to increase operation speed. Normally, use a setting of 0.
The upper limit of the set value is restricted to the smaller value of the corresponding damping
frequency or (2000 damping frequency).
Refer to 11-5 Damping Control on page 11-17 for more information on settings.
Set
damping frequency 4 to suppress vibration at the end of the load in damping control.
Measure the frequency of vibration at the end of the load and make the setting in units of 0.1 Hz.
Setting frequency is 1.0 to 200.0 Hz. The function is disabled if the setting is 0 to 0.9 Hz.
Refer to 11-5 Damping Control on page 11-17 for more information on settings.
First set
Damping Frequency 4 (3220 hex). Then reduce the setting if torque saturation occurs or
increase the setting to increase operation speed. Normally, use a setting of 0.
The upper limit of the set value is restricted to the smaller value of the corresponding damping
frequency or (2000 damping frequency).
Refer to 11-5 Damping Control on page 11-17 for more information on settings.
3217 hex
Damping Filter 2 Setting
Setting range 0 to 1000 Unit 0.1 Hz
Default setting
0 Data attribute B
Size 2 bytes (INT16) Access RW PDO map Not possible.
3218 hex
Damping Frequency 3
Setting range 0 to 2000 Unit 0.1 Hz
Default setting
0 Data attribute B
Size 2 bytes (INT16) Access RW PDO map Not possible.
3219 hex
Damping Filter 3 Setting
Setting range 0 to 1000 Unit 0.1 Hz
Default setting
0 Data attribute B
Size 2 bytes (INT16) Access RW PDO map Not possible.
3220 hex
Damping Frequency 4
Setting range 0 to 2000 Unit 0.1 Hz
Default setting
0 Data attribute B
Size 2 bytes (INT16) Access RW PDO map Not possible.
3221 hex
Damping Filter 4 Setting
Setting range 0 to 1000 Unit 0.1 Hz
Default setting
0 Data attribute B
Size 2 bytes (INT16) Access RW PDO map Not possible.