EasyManua.ls Logo

Omron SJDE-ANA-OY - Substatus Field Specifications: SUBSTATUS

Omron SJDE-ANA-OY
170 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.5 Command Data Field
104
Emergency stop switch input signal (E-STP)
Indicates the emergency stop switch input signal status.
4.5.6 Substatus Field Specifications: SUBSTATUS
The substatus field is used to monitor the subcommand status with the eighteenth byte reserved area
of the subcommands.
Substatus Field
D10 Status
0
Emergency stop switch input OFF
1
Emergency stop switch input ON
D7 D6 D5 D4 D3 D2 D1 D0
−−−−−SBCM-
DRDY
SBWARNG SBALM
Bit Name Description Set
Value
Status
D0 SBALM Subcommand alarm occurrence
0
None
1
Alarm occurs.
D1 SBWARNG Subcommand warning occurrence
0
None
1
Warning occurs.
D2 SBCMDRDY Subcommand ready
(Subcommand reception enabled)
0
Subcommands cannot be
received. (busy)
1
Subcommand can be received.
(ready)
TOEP_C710806_03A_1_0.book Seite 104 Montag, 2. Juli 2007 3:55 15

Table of Contents