EasyManua.ls Logo

Omron SJDE-ANA-OY - Replacement of Cooling Fan

Omron SJDE-ANA-OY
170 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9.3 Replacement of Cooling Fan
157
9.3 Replacement of Cooling Fan
400 W SERVOPACKs
• Do not open the SERVOPACK case for 5 minutes after the power supply indicator (PWR LED)
goes out. High voltage may remain in the SERVOPACK after the power supply has been turned
OFF.
• After turning OFF the power supply, wait 15 minutes before replacing the cooling fan.
Failure to observe this caution may result in burns because the heat sink is hot.
• Mount the cooling fan in the correct way.
• Improper mounting may result in the breakdown of the SERVOPACK.
1. Open the front cover of the SER-
VOPACK.
Press the tip of a flathead
screwdriver against each of the
two notches on the SERVO-
PACK to dislodge the hooks.
Insert the tip of a flathead
screwdriver into the two
notches on the SERVOPACK
one at a time and pry the front
cover off.
2. Open the case of the SERVO-
PACK.
Insert the tip of a flathead screw-
driver into the two notches on the
SERVOPACK one at a time and
pry the hooks loose.
CAUTION
Front cover
Case
TOEP_C710806_03A_1_0.book Seite 157 Montag, 2. Juli 2007 3:55 15