3.4 Main Circuit Wiring
41
Connector Pin Arrangement
3.4.6 Wiring the MECHATROLINK-II Communication Connectors
(CN6A and CN6B)
Number of Stations
A maximum of 30 slave stations can be connected when a repeater is connected. The maximum num-
ber of slave stations that can be connected is determined by the MECHATROLINK-II communications
settings. Refer to 3.8 Setting MECHATROLINK-II Communications for details.
Communication Cables
Use the cables specified in the table below.
Cable Length
The total cable length must be 50 m max. The cable length between stations must be 0.5 m min.
Terminator
Install a terminator on the SERVOPACK connected at the end of communication cable.
Typ e Model Length
MECHATROLINK Communication
Cable
(with connectors at both ends, without
ferrite core)
JEPMC-W6002- Specify the length in .
Refer to Page 31 for details.
JEPMC-W6002--E
(Compliant with RoHS
Directive)
MECHATROLINK Communication
Cable
(with connectors at both ends, with
ferrite core)
JEPMC-W6003-
JEPMC-W6003--E
(Compliant with RoHS
Directive)
Ter min at or Type Connector Type
MECHATROLINK-II Terminator JEMPC-W6022
JEMPC-W6022-E (Compliant with RoHS Directive)