9.1 Regular Inspections
156
9 Inspections
9.1 Regular Inspections
For inspection and maintenance of the SERVOPACK, follow the inspection procedures in the following
table at least once every year. Other routine inspections are not required.
9.2 Part’s Life Expectancy
The following electric or electrical parts are subject to mechanical wear or deterioration over time.
If an unusual noise or vibration occurs, refer to the life expectancy table and contact your Omron
Yaskawa representative. After examining the part in question, we will determine whether the parts
should be replaced or not. When the part has expired before the expected time, further inspection will
be required.
Note: 1. The life expectancy listed in the table is a reference period that may be affected
by the environmental and operating conditions.
2. The recommended models of the replacement cooling fans are:
Item Frequency Procedure Comments
Exterior At least once a year Check for dust, dirt, and oil on
the surfaces.
Clean with cloth or com-
pressed air.
Loose Screws Check for loose connector
screws.
Tighten any loose screws.
Part Life Expectancy Comments
Cooling Fan 30,000 hours Life depends on operation conditions. Check that there is no
unusual noise or vibration when inspecting.
SERVOPACK Model Manufacturer
SJDE-04ANA-OY JZSP-CHF08-1 SUN-WA TECHNOS
CORPORATION
SJDE-08ANA-OY JZSP-CHF08-2