No.19S185-01
44/68
STC-MBE132POE / STC-MCE132POE
Product Specifications and User’s Guide
10.8 Gamma correction
The gamma correction is changeable.
GenICam Parameters
Gamma IFloat Type Gamma correction
Range: 0 to 4.0
Default: 1.0
10.9 ROI (Region of Interest)
The specified region of image can be output from camera with ROI function.
GenICam Paramters
Width IInteger Type Width (horizontal size) of output image (in pixel)
Range: 8 to 1,280
Default: 1,280
Adjustable steps: 8
(“Width” + “Offset X”) should not exceeded maximum width.
Height IInteger Type Height (vertical size) of output image (in line)
Range: 2 to 1,024
Default: 1,024
Adjustable steps: 2
(“Height” + “Offset Y”) should not exceeded maximum height.
OffsetX IInteger Type Horizontal offset for output image (in pixel)
Range: 0 to 1,272
Default: 0
Adjustable steps: 8
OffsetY IInteger Type Vertical offset for output image (in line)
Range: 0 to 1,022
Default: 0
Adjustable steps: 2
The ROI region settings are below:
Height
ROI region