6-19
The parameter n40 for multi-function output must be set for the frequency detection
function.
H Frequency Detection
The
parameter
n40 for multi-function output must be set for frequency detection out
-
put.
Set value: 2 for frequency detection
Frequency Detection Operation
Output
frequency
Detection width ±2 Hz
Reset width ±4 Hz
Frequency reference
Time
Frequency
detection
Time
H Frequency Detection Levels 1 and 2
The
parameter
n40 for multi-function output must be set for frequency detection out
-
put.
Set value: 4 for frequency detection level 1 (Output frequency
n58)
Set value: 5 for frequency detection level 2 (Output frequency
n58)