Program (Unit #0)
Turns ON the valid initial
positioning no. bit for 1
scan with the next
START following the
end of the bank.
Start switch
10501 (Bank End flag)
10000 03000 03101
03100
03100
10000 03000
03101
03100
03101
03101
03100
#0 assigned
switch
DIFU (13) 10000
DIFU (13) 03000
MOV (21)
#0000
101
MOV (21)
#0005
101
DIFU (13) 10001
Designates #0 as the
next positioning action
after the bank ends
#5 assigned
switch
Designates #5 as the
next positioning action
after the bank ends
Using a Multiple Bank Program Section 5–10