5-28
5
F1-22
Magnet posi-
tion offset
Sets the Offset between the rotor
magnet and encoder zero position.
0 to 360 60 ° No - - - A 3B1H 6-73
Mag Theta
Comp
F1-25
Encoder copy
selection
Used to memorize encoder and
motor data in the encoder memory
(for Hiperface and EnDat encod-
ers)
0:Normal operation
1:WRITE (Inverter to encoder)
2:COPY (Encoder to inverter)
3:VERIFY
0 to 3 0 No - - - A 3B4H 6-75
Enc Copy Sel
F1-26
Encoder copy
write permis-
sion selection
Sets wether saving parameters in
the encoder is permitted or not.
0:Write prohibited
1:Write permitted
0 or 1 0 No - - - A 3B5H 6-75
Write Allow-
able
*1. Can be set only if HIPEFACE
y
is selected as encoder type.
Param-
eter
Num-
ber
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO-
BUS
Register
Page
V/f
Open
Loop
Vector
Closed
Loop
Vector
Closed
Loop
Vector
(PM)
Display