Configuration attributes Crocus CNV
90 Reference manual
6.4.1 General interface configuration attributes
crocusIfConv<2m/Nx64><Tt/Cv>/<dteInterface>/alarmMask
The alarmMask attribute enables or disables for each alarm of the corresponding object, whether it is
communicated to the central management system (e.g. HP OpenView
®
) or not.
For more information on …
• alarms in general, refer to Section 9.2 Introducing the alarm attributes.
• the alarms of the <dteInterface> object, refer to Section 9.5 - Interface alarms.
Note that the underlying alarms may differ for each interface.
crocusIfConv<2m/Nx64><Tt/Cv>/<dteInterface>/alarmLevel
With this attribute, a priority level can be assigned to each alarm of the corresponding object. The alarm
level ranges from 0 up to 254, where 0 is the lowest and 254 is the highest priority level.
crocusIfConv<2m/Nx64>Cv/<dteInterface>/alarmContactHighMask
This attribute is only present on the CV.
The alarmContactHighMask attribute enables or disables for each alarm of the corresponding object,
whether:
• a visual indication is generated (blinking error LED)
• the alarm contacts on the CN4 card nest are driven.
crocusIfConv<2m/Nx64>Cv/<dteInterface>/alarmContactLowMask
This attribute is only present on the CV.
The alarmContactLowMask attribute enables or disables for each alarm of the corresponding object, whether:
• a visual indication is generated (blinking error LED)
• the alarm contacts on the CN4 card nest are driven.
crocusIfConv<2m/Nx64><Tt/Cv>/<dteInterface>/txClk default: <interface dependent>
Use this attribute to select the clocking mode of the DTE interface its transmit clock. For more information
on clocking, refer to Section 5.3 - Configuring the clocking mode.
crocusIfConv<2m/Nx64><Tt/Cv>/<dteInterface>/rxClk default: fromLine
Use this attribute to select the clocking mode of the DTE interface its receive clock. For more information
on clocking, refer to Section 5.3 - Configuring the clocking mode.
• crocusIfConv<2m/Nx64>Tt/ remoteAlarmMask
This attribute is only present on the TT.
The remoteAlarmMask attribute enables or disables for each alarm of the corresponding object, whether:
• a visual indication is generated (blinking error LED).
• an alarm is sent to the remote Crocus CNV.
By default, all the alarms in the remoteAlarmMask are set to disabled.