Crocus CNV Technical specifications
Reference manual 153
12.5 Power requirements
The input power recommendations are:
230 Vac +/- 10%, 45 – 60 Hz
115 Vac +/- 10%, 45 – 60 Hz
48 Vdc (36 – 72 Vdc)
Maximum power consumption:
Crocus 2M/Nx64 CNV CV: 7.2 W
Crocus Nx64 CNV TT: 2.2 W
12.6 Mechanical dimensions
The mechanical dimensions are as follows:
Dimensions Table Top Card Version CN4 Card Nest
height (mm) 45 20 270
width (mm) 220 235 445 without rackmounts
depth (mm) 215 excl. interface
235 incl. interface
300 330 excl. interface
350 incl. interface
weight (kg) 0,75 (excl. interface) 1 6.1 (excl. cards)
12.7 Environmental compliance
Storage conditions: ETSI ETS 300 019-1-1 Class 1.1. In addition, the storage temperature has to be
between -25 to +70°C
Transport conditions : ETSI ETS 300 019-1-2 Class 2.3
Stationary use conditions: ETSI ETS 300 019-1-3 Class 3.2. In addition, the requirements below
apply:
relative humidity 5 to 95% non-condensing and ambient operational temperature -5 to 45°C
or
relative humidity 0 to 95% non-condensing and ambient operational temperature -10 to 50°C
Maximum altitude: 3000m
International protection (IP) class of protection against solid and liquids: IP40

Table of Contents