Performance attributes Crocus CNV
116 Reference manual
8.3 G703 onboard performance attributes
crocusIfConv<2m/Nx64><Tt/Cv>/g703OnBoard/errorCount
This attribute displays the amount of detected errors since the start of an ET, AL-ET or RDL-ET test.
Every time a new ET, AL-ET or RDL-ET is started, the errorCount attribute is reset to 0.
crocusIfConv<2m/Nx64><Tt/Cv>/g703OnBoard/h2Performance
This structured value displays the 2 hours performance summary related to the performance. The
h2Performance structured value elements are the following:
Element For the corresponding period, this value displays …
sysUpTime
the elapsed time since the last cold boot.
lineAttenuationMin(dB)
the minimum G703 line attenuation that was measured.
lineAttenuationMax(dB)
the maximum G703 line attenuation that was measured.
lineAttenuationAvrg(dB)
the average G703 line attenuation that was calculated.
crocusIfConv<2m/Nx64><Tt/Cv>/g703OnBoard/h24Performance
This structured value displays the 24 hours performance summary related to the performance. The
h24Performance elements are the same as the h2Performance elements.