Crocus CNV Alarm attributes
Reference manual 129
9.3 General alarms
Refer to Section 9.2 Introducing the alarm attributes. for the general alarm attributes.
crocusIfConv<2m/Nx64><Tt/Cv>/alarmInfo
The different alarms related to the crocusIfConv<2m/Nx64><Tt/Cv> object together with their explanation and
their default alarmMask and alarmLevel value are given in the following table:
Default value The alarm … is generated …
alarmMask alarmLevel
notResponding
when the Crocus CNV does not respond on the
polling session of the Orchid 1003 LAN.
enabled 4
alarmSyncLoss
when the internal alarm buffer overflows.
enabled 4
configChanged
when the configuration of the Crocus CNV is
changed.
disabled 1
access
when a TMA connection is made through the
auxiliary connector of the Crocus CNV (not when a
TMA connection is made via the Orchid 1003 LAN).
disabled 1
remoteAlarm
when the remote Crocus CNV is in alarm condition.
This allows you to perform alarm signalling using
the alarmContactLowMask and alarmContactHighMask
attributes. This is particularly interesting when you
do not have a central management system.
This alarm exists on the Crocus Nx64 CNV only.
Moreover, it only functions in framed mode.
disabled 0
powerSupply1CvFail
when the upper power supply in the CN4 card nest
is not present or fails.
This alarm exists on the CV only.
disabled 3
powerSupply2CvFail
when the lower power supply in the CN4 card nest
is not present or fails.
This alarm exists on the CV only.
disabled 3
powersupply48vfail
when the directly connected -48 Vdc on the CN4
card nest is no longer present. This means that the
115/230 Vac back-up power supply has taken over.
This alarm exists on the CV only.
disabled 3
unknownState
each time a new Crocus CNV is added to the
network and before the Orchid 1003 LAN has
completed a first successful polling session.
disabled 0
coldBoot
each time the Crocus CNV performs a cold boot.
disabled 1
warmBoot
each time the Crocus CNV performs a warm boot.
disabled 1