Configuration attributes Crocus CNV
78 Reference manual
6.2 General configuration attributes
crocusIfConv<2m/Nx64><Tt/Cv>/sysName default: <empty>
This is a field where you can assign a name to the Crocus CNV. The field has a limit of 64 characters.
This is a SNMP MIB2 parameter.
crocusIfConv<2m/Nx64><Tt/Cv>/sysContact default: <empty>
This is a field where you can fill in the name of a contact person together with information on how to
contact this person. The field has a limit of 64 characters.
This is a SNMP MIB2 parameter.
crocusIfConv<2m/Nx64><Tt/Cv>/sysLocation default: <empty>
This is a field where you can fill in the physical location of the Crocus CNV. The field has a limit of 64
characters.
This is a SNMP MIB2 parameter.
crocusIfConv<2m/Nx64><Tt/Cv>/bootFromFlash default: auto
The Crocus CNV has two flash memory banks. Each flash memory can contain a complete software
version, but only one can be active. You can choose from the following settings:
Value If you boot the Crocus CNV then …
flash1
the first flash memory bank is activated.
flash2
the second flash memory bank is activated.
auto
the Crocus CNV automatically chooses the flash memory bank containing the most
recent firmware, by comparing the firmware version numbers.
For a Crocus CNV CV, the bootFromFlash attribute only works on converter A. Although the bootFromFlash
attribute is also visible in the containment tree of converter B, its setting is ignored. Both converter A and
B use the same firmware.