TMA subsystem picture of the Crocus CNV Crocus CNV
136 Reference manual
The table below gives an overview of the subsystem picture elements and what they indicate.
Element Description
LED indicators They reflect the actual status of the Crocus CNV. The LED indication on the
subsystem picture corresponds with the LED indication on the Crocus CNV
itself. For more information on the interpretation of the LEDs, refer to Section 2.8
- Front panel LED indicators.
G703 onboard
interface status
This reflects the status of the onboard G703 interface. Depending on which
interface connector you selected (the RJ45 on the front or the connector block at
the back), the front or rear connector will be coloured.
The possible indications are:
Colour Explanation
green
No alarm of the g703OnBoard object is active.
red
An (unmasked) alarm of the g703OnBoard object is active.
The colours of the onboard G703 interface only change if the alarms related to
the g703OnBoard object are set to enabled in the alarmMask. Refer to Section 6.3 -
G703 onboard configuration attributes.
DTE interface This reflects the status of the DTE interface. The possible indications are:
Colour Explanation
none If the DTE interface slot in the subsystem picture is blank, it
means that no DTE interface module was present at power-
up.
green
No alarm of the <dteInterface> object is active.
red
An (unmasked) alarm of the <dteInterface> object is active.
The layout of the connector also gives an indication of the type of DTE interface
which is currently used in the Crocus CNV.
The colours of the DTE interface only change if the alarms related to the
<dteInterface> object are set to enabled in the alarmMask. Refer to Section 6.4 -
Interface configuration attributes.