Configuration attributes Crocus CNV
86 Reference manual
crocusIfConv<2m/Nx64><Tt/Cv>/g703OnBoard/alarmMask
The alarmMask attribute enables or disables for each alarm of the corresponding object, whether it is
communicated to the central management system (e.g. HP OpenView
®
) or not.
For more information on …
alarms in general, refer to Section 9.2 Introducing the alarm attributes.
the alarms of the g703OnBoard object, refer to Section 9.4 - G703 onboard alarms.
crocusIfConv<2m/Nx64><Tt/Cv>/g703OnBoard/alarmLevel
With this attribute, a priority level can be assigned to each alarm of the corresponding object. The alarm
level ranges from 0 up to 254, where 0 is the lowest and 254 is the highest priority level.
crocusIfConv<2m/Nx64>Cv/g703OnBoard/alarmContactHighMask
This attribute is only present on the CV.
The alarmContactHighMask attribute enables or disables for each alarm of the corresponding object,
whether:
a visual indication is generated (blinking error LED)
the alarm contacts on the CN4 card nest are driven.
crocusIfConv<2m/Nx64>Cv/g703OnBoard/alarmContactLowMask
This attribute is only present on the CV.
The alarmContactLowMask attribute enables or disables for each alarm of the corresponding object, whether:
a visual indication is generated (blinking error LED)
the alarm contacts on the CN4 card nest are driven.
crocusIfConv<2m/Nx64><Tt/Cv>/g703OnBoard/longHaul default: enabled
The onboard G703 interface is equipped with a driver. This enables you to cover long distances. The
driver can be enabled or disabled.
The distances that can be covered are in the order of:
2.5 km using a cable with a diameter of 0.6 mm
1.25 km using a cable with a diameter of 0.4 mm.
Important remark
On a Crocus 2M CNV CV and on a Crocus Nx64 CNV CV in unframed mode, it is not possible to start an
RDL test or receive a DL test from the remote side when the device is strapped in short haul (i.e. longHaul
= disabled). However, it is possible to start a DL test directly on the device itself.