Configuration attributes Crocus CNV
88 Reference manual
crocusIfConv<2m/Nx64><Tt/Cv>/g703OnBoard/name default: <empty>
Use the name attribute to assign an administrative name to the interface.
crocusIfConv<2m/Nx64><Tt/Cv>/g703OnBoard/aisDetection default: enabled
Use this attribute to enable or disable the detection of the Alarm Indication Signal.
crocusIfConv<2m/Nx64><Tt/Cv>/g703OnBoard/sqTime default: 00000d 00h 01m 00s
Use this attribute to set the signal quality time. This is the period (in days, hours, minutes and seconds)
during which the signal quality threshold is measured.
If the sqThreshold value, i.e. the number of errored seconds, is exceeded within the sqTime, then a signal
quality (sq) alarm is generated. For example, if 10 (default) or more errored seconds occur within 1
minute (default), then a signal quality alarm is generated.
The sqTime value ranges from 00000d 00h 00m 00s up to 24855d 03h 14m 07s.
crocusIfConv<2m/Nx64><Tt/Cv>/g703OnBoard/sqTreshold default: 32 bits
Use this attribute to set the signal quality threshold. This is the number of errored seconds for which a
signal quality alarm is generated.
If the sqThreshold value, i.e. the number of errored seconds, is exceeded within the sqTime, then a signal
quality (sq) alarm is generated. For example, if 10 (default) or more errored seconds occur within 1 minute
(default), then a signal quality alarm is generated.
The sqThreshold value ranges from 0 up to 65535.
crocusIfConv<2m/Nx64>Tt/ remoteAlarmMask
This attribute is only present on the TT.
The remoteAlarmMask attribute enables or disables for each alarm of the corresponding object, whether:
• a visual indication is generated (blinking error LED).
• an alarm is sent to the remote Crocus CNV.
By default, all the alarms in the remoteAlarmMask are set to disabled.