Read Element Status
Julyl 2017 Command Set 201
Data Transfer Element Descriptor When DvcID = 0 Definitions:
Element Address This field contains the element address of the data transfer element reported.
Access This bit indicates access is allowed to the data transfer element by the hand:
0 = Access is not allowed to the tape drive element by the hand. This will be
the case when a cartridge tape is loaded and in use by the tape drive.
The tape is set to ejected before i t becomes accessible.
1 = The tape drive is accessible.
Except This bit indicates the operational state of the data transfer element:
0 = The data transfer element is in the normal state.
1 = The data transfer element is in an abnormal state, and the Additional Sense
Code and the Additional Sense Code Qualifier fields contain information
regarding the abnormal state. Other fields in this descriptor might be invalid,
and should be ignored.
Full This bit indicates if the data transfer element contains a cartridge tape:
0 = The data transfer element does not contain a cartridge tape.
1 = The data transfer element does contain a cartridge tape.
Additional Sense Code This field is valid only if the Except bit is set. In the case of an exception, it
contains an ASC as defined for Request Sense data.
Additional Sense Code
Qualifier
This field is valid only if the Except bit is set. In the case of an exception,
it contains an ASCQ as defined for Request Sense data.
SValid This bit indicates if the Source Element Address and Invert fields are valid:
0 = The Source Element Address and Invert fields are not valid.
1 = The Source Element Address and Invert fields are valid.
Invert The library does not support multi-sided media and returns a value of 0.
ED 0 = The element is enabled (for example a magazine or drive has been installed
or has been logically enabled)
1 = The element is disabled
Medium Type This field provides the type of medium currently present in the element as
determined by the medium changer.
The library returns the following values:
0h = Unspecified - the medium changer cannot determine the medium type.
1h = Data Medium
2h = Cleaning Medium
Source Storage Element
Address
This field is valid only if the SValid bit i s 1. It contains the address of the last
element from which the data cartridge was moved.

Table of Contents

Other manuals for Oracle storagetek sl150

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oracle storagetek sl150 and is the answer not in the manual?

Oracle storagetek sl150 Specifications

General IconGeneral
BrandOracle
Modelstoragetek sl150
CategoryStorage
LanguageEnglish

Related product manuals