42
Settings of MEXE02
9 Settings of
MEXE02
Functions of the product can be extended by extension setting of operation data and setting of parameter using the
MEXE02
.
9.1 Timing to update data when the setting is changed
When a parameter is written to the driver, it is saved in the non-volatile memory. The parameter saved in the non-
volatile memory is stored even after the power supply is turned o. When a parameter is changed, the timing to update
the changed value varies depending on the parameter. See the following four types.
•
Update immediately .......................................Recalculation and setup are immediately executed when the parameter is written.
•
Update after operation stop ........................Recalculation and setup are executed when the operation is stopped.
•
Update after executing conguration .....Recalculation and setup are executed after conguration is executed.
Conguration is executed using the
MEXE02
.
•
Update after turning on the power again ... Recalculation and setup are executed after the power is turned on again.
Notation rules
In this chapter, each update timing is represented in an alphabet.
A: Update immediately
B: Update after operation stop
C: Update after executing conguration or turning the power again
D: Update after turning on the power again