35
Operation
z
Timing chart when power is input
Signal is output
OFF
ON
OFF
Output signal
1.0 s or less
1.0 s or more
Input enabled
ON
Input signal
7.7 Rotation direction of the motor output shaft
The rotation direction of the motor output shaft represents the direction when
viewed from the motor output shaft.
The motor rotation direction can be changed using the
MEXE02
.
The gure shows when the "Motor rotation direction" parameter is set to "+=CW."
"Motor rotation direction" parameter
⇒
p.51
FWD input signal
(CCW)
Rotation direction of the gearhead output shaft
The rotation direction of the gearhead output shaft varies depending on the type or the gear ratio of the gearhead.
Check the operating manual of the motor for the rotation direction of the gearhead output shaft.
7.8 Multi-speed operation
Multi-speed operation can be performed by switching the ON-OFF status
of the M0 to M2 inputs.
The M0 and M1 inputs are assigned at the time of shipment.
If the M0 to M2 inputs are assigned to the CN2, variable speed operation
using up to 8 operation data can be performed.
High spee
Low speed
Operation data M2 M1 M0
0 OFF OFF OFF
1 OFF OFF ON
2 OFF ON OFF
3 OFF ON ON
4 ON OFF OFF
5 ON OFF ON
6 ON ON OFF
7 ON ON ON
z
When 4-speed operation is performed with the operation data No.0 to No.3
ON
OFF
ON
OFF
ON
FWD
input
No.0 No.1 No.2 No.3
M1
input
M0
input
Motor movement
No.0 No.1 No.2 No.3
No.3
Eective operation data No.