9.7 I/O function selection
C: Update after executing the conguration
Parameter name Description Setting range Factory setting Update
DIN0 input function selection
Selects the input signal to
assign to the direct I/O (DIN0
to DIN5).
Refer to "1 Input
function selection."
FWD (START/STOP)
*
C
DIN1 input function selection REV (RUN/BRAKE)
*
DIN2 input function selection STOP-MODE (FWD/REV)
*
DIN3 input function selection M0
DIN4 input function selection M1
DIN5 input function selection ALM-RST
DIN0 logic level setting
Sets the logic level for the
direct I/O (DIN0 to DIN5).
Not invert,
Invert
Not invert
DIN1 logic level setting Not invert
DIN2 logic level setting Not invert
DIN3 logic level setting Not invert
DIN4 logic level setting Not invert
DIN5 logic level setting Not invert
DOUT0 output function selection
Selects the signal to assign
to the direct I/O (DOUT0 to
DOUT3).
Refer to "2 Output
function selection."
SPEED-OUT
DOUT1 output function selection ALM-B
DOUT2 output function selection TLC
DOUT3 output function selection DIR
DOUT0 logic level setting
Sets the logic level for the
direct I/O (DOUT0 to DOUT3).
Not invert,
Invert
Not invert
DOUT1 logic level setting Not invert
DOUT2 logic level setting Not invert
DOUT3 logic level setting Not invert
*
If the 3-wire input mode is selected with the "Operation input mode selection" parameter, the signal in the parentheses ( )
will be applied.
Setting range of the function selection parameter
1 Input function selection
Refer to p.22 for details.
Not used
ALM-RST
INFO-CLR
HMI
TL
M0
M1
EXT-ERROR
FWD (START/STOP)
*
REV (RUN/BRAKE)
*
M2
STOP-MODE (FWD/REV)
*
H-FREE
*
If the 3-wire input mode is selected with the "Operation input mode selection" parameter, the signal in the parentheses ( )
will be applied.
2 Output function selection
Refer to p.25 for details.
Not used
ALM-A
ALM-B
MOVE
INFO
TLC
VA
SPEED-OUT
DIR
INFO-DRVTMP
INFO-OVOLT
INFO-UVOLT
INFO-LOAD
INFO-SPD
INFO-SET-E
INFO-DRV
INFO-TRIP
INFO-ODO
INFO-TRQ-DE
INFO-SPD-DE
INFO-PTIME
INFO-PCOUNT
INFO-DSLMTD
INFO-IOTEST
INFO-CFG
INFO-RBT