53
Settings of MEXE02
9.5 Alarm and information settings
Refer to p.62 for details about information.
A: Update immediately, C: Update after executing conguration
Parameter name Description Setting range
Factory
setting
Update
Overload alarm detection time
Sets the detection time of the overload
alarm.
0.1 to 10.0 [s] 10.0 A
Prevention of operation at power-on alarm
Sets whether to enable or disable the
"prevention of operation at power-on
alarm." Refer to p.60 for alarms.
Disable,
Enable
Enable C
Information auto clear
This is a function to clear the
information status automatically to turn
the INFO output signal OFF when the
cause of the generated information was
removed.
Disable,
Enable
Enable
A
Driver temperature information
Sets the generation condition of the
driver temperature information.
40 to 85 [°C] 85
Overvoltage information
Sets the generation condition of the
overvoltage information.
18.0 to 38.0 [VDC] 38.0
Undervoltage information
Sets the generation condition of the
undervoltage information.
18.0 to 38.0 [VDC] 18.0
Load information
Sets the generation condition of the
load information.
0 (disable),
1 to 200 [%]
0
Speed information
Sets the generation condition of the
speed information.
0 (disable),
1 to 5200 [r/min]
0
Tripmeter information
Sets the generation condition of the
tripmeter information.
0.0 (disable),
0.1 to 99999999.9 [kRev]
0.0
Odometer information
Sets the generation condition of the
odometer information.
0.0 (disable),
0.1 to 99999999.9 [kRev]
0.0
Main power supply time information
Sets the generation condition of the
main power supply time information.
0 (disable),
1 to 999,999,999 [min]
0
Main power supply count information
Sets the generation condition of the
main power supply count information.
0 (disable),
1 to 999,999,999 [times]
0
INFO action (Driver temperature information
(INFO-DRVTMP))
This is a function to select whether the
INFO output will be output and the
LED will blink when corresponding
information is generated.
INFO action is not applied
 Information bit:
Indicates on the
MEXE02
display
 INFO output: OFF
 LED: Unlit
INFO action is applied
 Information bit:
Indicates on the
MEXE02
display
 INFO output: ON
 LED: Blink
INFO
action
is
applied
INFO action (Overvoltage information (INFO-
OVOLT))
INFO action (Undervoltage information (INFO-
UVOLT))
INFO action (Load information (INFO-LOAD))
INFO action (Speed information (INFO-SPD))
INFO action (Operation data setting error
information (INFO-SET-E))
INFO action (Operation prohibited information
(INFO-DRV))
INFO action (Tripmeter information (INFO-TRIP))
INFO action (Odometer information (INFO-ODO))
INFO action (Torque limiting value setting error
information (INFO-TRQ-DE))
INFO action (Rotation speed setting information
(INFO-SPD-DE))
INFO action (Main power supply time information
(INFO-PTIME))
INFO action (Main power supply count information
(INFO-PCOUNT))
INFO action (Operation start limiting mode
information (INFO-DSLMTD))
INFO action (I/O test mode information (INFO-
IOTEST))
INFO action (Conguration request information
(INFO-CFG))
INFO action (Power cycling request information
(INFO-RBT))