MEXE02
8.3 Test operation
Teaching/remote operation
A motor can be operated using the
MEXE02
. The motor operation can be checked before connecting to a
programmable controller.
Also, the teaching function of the operation data can be performed.
The PWR/ALM LED on the driver blinks in orange when teaching/remote operation is started.
Note
While teaching/remote operation is performed, the motor is operated based on the data set in the teaching data.
If the motor is used in a state where the output torque is limited, check the setting of the teaching data before
performing teaching/remote operation.
If the communication is disconnected while the motor rotates, the motor stops instantaneously.
I/O test
I/O signals of D-I/O can be tested.
Input signals can be monitored, and output signals can forcibly be turned ON or OFF to check the connection with a
programmable controller.
The rotation speed or torque limiting value set by the internal potentiometer or external setting device can be checked
before operating the motor.
The PWR/ALM LED on the driver blinks in orange when I/O test is started.
Refer to the operating manual of the
MEXE02
for the operating method and others.
Note
Output signals can forcibly be turned ON or OFF with I/O test. Therefore, other devices connected to the applicable
product may operate. Before operation, check the condition of the surrounding area to ensure safety.
z
Items possible to check on the I/O test monitor window
Input values from the external setting device and setting values of operation data converted from the input values are
shown.
Even if the motor is not rotated actually, the setting values (rotation speed, torque limiting value, acceleration time,
deceleration time) over the input values can be checked.
Values before applying the limiter function such as the speed upper limit, speed lower limit, and torque limiting
maximum value are shown for the converted values.
Setting device name Item
Internal potentiometer
VR1
Rotation speed
Acceleration time/Deceleration time
Torque limiting value
VR2
Rotation speed
Acceleration time/Deceleration time
Torque limiting value
External potentiometer
External analog setting device
Input voltage
Rotation speed
Torque limiting value
PWM signal input
Duty cycle
Rotation speed
Frequency
Torque limiting value